SANKALPELECTRICALS Enquiry listList

Kaycee · Contactors & switches

Kaycee Rotary Cam Switches

Price on enquiry

Packet-type hand-operated rotary cam switches from 6 A to 32 A, including instrument selector and motor control switches.

Or call +91 98203 16440

Key features

  • Multi-position, multi-pole circuits assembled on packet principle
  • Ratings 6 A, 10 A, 12 A, 25 A AC and 6 A / 25 A DC; 32 A also listed
  • Switching angles 30°, 45°, 60° and 90°; spring return restricted to 30°
  • Panel mounting standard; base mounting on request
  • Voltmeter and ammeter selector switches and motor control switches
  • Make before break contacts against specific requirements; CE approved

Applications

  • Switching, controlling and starting of 3-phase AC squirrel cage induction motors
  • Voltmeter and ammeter selection

Technical specifications

Electrical data
Rating6 A / 440 V AC, 10 A / 440 V AC, 6 A / 250 V DC (thermal), 12 A / 380 V AC, 25 A / 250 V AC, 10 A / 440 V AC, 25 A / 250 V DC (thermal), 32 A / 250 V AC
SpecificationIS 60947 Part I, III and V
Continuous current Ith10 A / 12 A / 25 A AC (make-break at rated current and voltage); 25 A and 6 A DC (thermal; make-break 0.5 A / 220 V DC)
Insulation voltage250 V DC, 550 V AC
Operational voltage220 V DC and 250 V AC, 380 V AC, 440 V AC
High voltage2.1 kV (r.m.s.)
Ambient temperature55°C
Frequency of operation240 cycles / hour
Mechanical life50,000 operations
Electrical life10,000 operations (rated thermal current 25 A DC); 10 A, 12 A and 25 A AC depend on application, frequency and load
IP testIP 55 from front
DC breaking capacity, 6 A DC type (10,000 operations)
50 V, 1 contactResistive 6*, inductive 10 ms 5, 20 ms 3.75, 40 ms 1.5
50 V, 2 contacts in seriesInductive 40 ms 5.00
110 V, 1 contactResistive 0.5, inductive 10 ms 0.6, 20 ms 0.37, 40 ms 0.25
220 V, 1 contactResistive 0.25, inductive 10 ms 0.12, 20 ms 0.07, 40 ms 0.05
DC breaking capacity, 25 A DC type (10,000 operations)
50 VResistive 20, inductive 10 ms 20, 20 ms 15*, 40 ms 6
110 VResistive 3, inductive 10 ms 2.5, 20 ms 1.5*, 40 ms 1
220 VResistive 1, inductive 10 ms 0.5, 20 ms 0.3, 40 ms 0.2
Coding system
First numberNumber of discs
Rating letterR 6 A/440 V AC; S 10 A/440 V AC; T 12 A/380 V AC; V 25 A/250 V AC or 10 A/440 V AC; M motor control up to 7.5 HP 3Ø 415 V AC; W 32 A; TD 6 A/250 V DC; MD 25 A/250 V DC
Next numbersNumber of poles, then angle of throw (3 = 30°, 4 = 45°, 6 = 60°, 9 = 90°)
Sequence lettersO on-off, B 2 way no off, BO 2 way with off, C 3 way no off, etc.; motor control K reversing, SD star/delta, PC pole changing, C system selector
Special codesX base mounting, AP ammeter selector, VP voltmeter selector, MB make before break, RM spring return, E with enclosure
Accessory suffixP pistol grip, W wing knob, B ball handle, LG centre key lock with lever handle, TG centre key lock with Tee handle
Standard switch range
Switching sequencesOn-off, and 2 to 12 way with or without off position; reversing with off
Poles1 to 4 (fewer on higher-way switches)
Mounting and enclosure
MountingFlush at back of panel as standard; base mounting on request
EnclosureOpen execution; 25 A switches and motor control switches up to 4 discs available in sheet steel enclosures
Spring return10–12 A cam switches with spring return up to 3 packets
25 A panel drillingØ 23 hole, 4 holes Ø 4.5 at 60 mm centres

Ordering codes

CodeRatingDescription
1S16O10 A ACOn-off, 1 pole, 60°
2S36O10 A ACOn-off, 3 pole, 60°
2S46O10 A ACOn-off, 4 pole, 60°
1V16O25 A ACOn-off, 1 pole, 60°
2V36O25 A ACOn-off, 3 pole, 60°
2V46O25 A ACOn-off, 4 pole, 60°
1MD 16O25 A DCOn-off, 1 pole, 60°
1TD 16O6 A DCOn-off, 1 pole, 60°
1S16BO10 A AC2 way with off, 1 pole, 60°
2S26BO10 A AC2 way with off, 2 pole, 60°
3S36BO10 A AC2 way with off, 3 pole, 60°
4S46BO10 A AC2 way with off, 4 pole, 60°
2V26BO25 A AC2 way with off, 2 pole, 60°
4V46BO25 A AC2 way with off, 4 pole, 60°
2S16C10 A AC3 way no off, 1 pole, 60°
2S14CO10 A AC3 way with off, 1 pole, 45°
5V34CO25 A AC3 way with off, 3 pole, 45°
3S16DO10 A AC4 way with off, 1 pole, 60°
3R39VP6 AVoltmeter selector, voltage between phases with off, 4 position 90°
3S39VP10 AVoltmeter selector, voltage between phases with off, 4 position 90°
3S49VN10 AVoltmeter selector, phases and neutral with off, 4 position 90°
4S44VPN10 AVoltmeter selector, between phases and each phase and neutral with off, 8 position 45°
4R39AP6 AAmmeter selector, current in each phase with off, 4 position 90°
4S39AP10 AAmmeter selector, current in each phase with off, 4 position 90°
6S56APN10 AAmmeter selector, each phase, neutral and leakage with off
2M6OBMotor controlOn-off, 2 position, 60°, 2 packets
3M6KBMotor controlReversing (1-OFF-1), 3 position, 60°, 3 packets
4M6SDBMotor controlStar/delta, 3 position, 60°, 4 packets
3M6PCBMotor controlTwo speed pole changing, separate windings (0-1-2), 3 packets
4M6PCBMotor controlTwo speed pole changing, Dahlander windings (0-1-2), 4 packets
7M4PCKBMotor controlTwo speed pole changing, reversing (2-1-0-1-2), 5 position, 45°, 7 packets
3M6CBMotor controlSystem selector (1-0-2), 3 position, 60°, 3 packets
2S26RO10 A ACReversing with off, 2 pole, 60°
3S36RO10 A ACReversing with off, 3 pole, 60°